Search

UVEO HF 400 Complete Plus Digital Radiography Solution

Selected for reliability, this user-friendly digital radiography system is an essential piece of equipment for every day diagnostic work. For vets who demand excellence and want to benefit from technology that makes delivering exceptional care easier and more efficient, this is an essential diagnostic imaging device.

The benefits you may be most interested in include:

  • Simple installation – can be installed in less than one day, minimizing downtime for your practice
  • Greatly enhanced four-way float range – (600mm Left-Right and 200mm Front-Back)
  • Lower electrical installation costs – the UVEO HF 400 Plus plugs into a regular 110 volt AC 15 Amp outlet so no additional wiring or expensive, electrical equipment is required.
  • Lower maintenance costs – Capacitors supply the electrical energy needed to provide full, high-performance x-ray output and offer much longer life than batteries.
  • Secure table-top – Mechanical table interlocks remain securely locked even when there is a power failure.

It is easy to connect the system to a network, and this enables remote, web-based diagnostics.

All units are mechanically designed to work with DR and CR digital systems up to size 43 cm x 43 cm (17 inch. x 17 inch.)

Table

  • Welded sheet metal structure painted with epoxy powder
  • 4-way Float Table
  • Pedal-controlled mechanical brake release
  • X-ray steel bucky tray
  • Inverter inside the table

Optional

  • Removable anti-scatter grid 103 lines/inch – Ratio 10:1 Film focus distance 100 cm
  • Cleat rope ties
  • X-ray hand switch
  • Self-leveling feet
  • Table top available in different lengths
  • Head rotation ± 90°
  • Accessory with variable angle for myelograph

X-RAY MONOBLOC

  • Power Supply 11 – 30 Kw 40 KHz
  • X-ray tube rotating anode RPM 2800 50 Hz
  • Anode diameter 60 mm
  • Focal spots 0.6 mm (11 Kw) – 1.3 mm (30 Kw)
  • Radiation leakage less than 3,5 micro SV/h according EN 60601-1-3

Generator

  • AC single-phase voltage of 110 Vac < 7 Amps
  • Frequency 60 Hz
  • Max output power 30 Kw
  • Frequency ripple 40 KHz
  • Max Voltage 125 kV
  • Max Current 400 mA
  • Exposure time range 2ms to 2 seconds

Operating System

  • KV setting: from 40 to 125 kVp
  • mAs setting: from 0.6 to 80 mAs
  • 2 point technique Kv – mAs
  • 3 point technique Kv – mA – mS
  • Anatomically programmed x-ray technique (APR)
  • Focal spot selection
  • Weight selection (KG)
  • Thickness selection (CM)

Collimator

  • Radiation protection up to 125 Kv
  • Manual adjustment for light field
  • Lamp timer 90 sec – automatic start
  • Field from 0 to 48 cm x 48 cm (18.8” x 18.8”)
  • LED Light