Day: 20 November 2026

The First Five Minutes: What Are We Missing During Emergency Triage?

A practical veterinary emergency triage refresher covering interpretation of PCV/TS, blood pressure, perfusion, initial diagnostics and emergency equipment preparation.

A dog arrives following trauma. Its mucous membranes are pale and the peripheral pulses feel weak, yet the initial packed cell volume is within the laboratory reference interval. Does that make significant haemorrhage unlikely?

Not necessarily.

The difficult part of emergency triage is rarely remembering which vital signs to collect. It is recognizing what our first measurements do not tell us, particularly while a patient is compensating for a developing problem. A normal PCV does not rule out acute blood loss. An apparently acceptable blood pressure does not establish adequate tissue perfusion. A quiet patient is not necessarily stable.

These distinctions matter in a general practice just as much as a referral ICU. We may have only a short window to recognize deterioration, begin stabilization, and decide whether the next intervention is safe.

Triage is not a shortened full physical examination

An initial survey prioritizes immediate threats to life. Respiratory effort and airway patency, cardiovascular perfusion, mentation and neurological status, and urinary abnormalities all deserve prompt attention. A cat reported to be vomiting may have an obstructed urinary tract. A patient after trauma may have occult blood loss even without obvious external bleeding.

The point is to decide what cannot wait, not to complete every investigation on arrival. The secondary survey, detailed history and definitive diagnostic plan follow once immediate problems have been addressed.

For unstable patients, the clinical examination and monitoring must work together. The availability of a Bionet veterinary patient monitor can support serial ECG, pulse oximetry and non-invasive blood-pressure assessment when the chosen model is appropriately configured. It does not replace palpating a pulse, assessing respiratory effort or recognizing a change in mentation.

A reassuring blood pressure may not mean adequate perfusion

In compensated circulatory shock, sympathetic responses may preserve arterial pressure while peripheral tissues remain underperfused. Blood pressure is only one part of the picture. Pulse quality, mucous membrane colour, capillary refill time, peripheral temperature, heart rate and mentation need to be considered together.

Cats can be particularly deceptive. Severe feline shock may be associated with hypothermia and bradycardia or a heart rate that is inappropriately normal for the degree of illness. Applying a simple ‘shock equals tachycardia’ rule to every cat may delay recognition.

Even the blood-pressure technique needs scrutiny. For Doppler and many oscillometric systems, cuff widths around 30–40% of the measurement-site circumference are commonly recommended, with manufacturer-specific instructions taking precedence. A cuff that is too narrow can overestimate the pressure; a cuff that is too wide can underestimate it. Movement, low perfusion and device-specific algorithms also influence reliability.

If a Bionet Brio X5 Vet Patient Monitor displays a result that does not fit the patient, first reassess the patient and the technique. Compatible cuffs across the sizes of patients you treat are as important as the monitor itself.

PCV and total solids: interpret the pair, not the isolated number

In acute haemorrhage, circulating red cells and plasma are lost together. The concentration of red cells in the remaining circulation may initially change very little. In dogs, splenic contraction may further affect the early PCV. A reduction can become more apparent as interstitial fluid shifts into the vascular compartment or after fluid administration.

The PCV–total-solids relationship may be informative, but it is not diagnostic by itself. A normal PCV with reduced total solids raises concern for acute haemorrhage in the appropriate context, but hypoalbuminaemia has other causes. Reduced PCV and total solids may accompany haemorrhage, dilution or concurrent anaemia and protein loss. Increased PCV and total solids may be compatible with dehydration.

A practical emergency database commonly incorporates PCV/TS, glucose, a blood smear and other tests guided by presentation. These results should be interpreted in light of timing, history, current treatment and serial trends.

For clinics doing PCV and blood-smear work in house, appropriate veterinary centrifuges and veterinary microscopes are relevant investments. Confirm that a particular centrifuge and rotor are validated for microhaematocrit use; a routine serum-separation centrifuge cannot simply be assumed suitable for that technique. A microscope is only useful for smear interpretation if the team has the equipment and competence to prepare and evaluate a satisfactory sample.

Establishing vascular access is not the same as determining fluid need

Intravenous access is often essential in a critically ill patient, but catheter selection should reflect vessel size, planned therapy and urgency. When rapid flow is needed, short, relatively wide-bore catheters generally offer lower resistance than narrow, long catheters, all else being equal. That principle does not mean the largest catheter is appropriate for every patient.

Once access is secured, the plan must distinguish resuscitation, replacement of dehydration, maintenance and ongoing losses. The 2024 AAHA Fluid Therapy Guidelines emphasize that fluids are prescribed treatments, not harmless background support. The amount and rate should be individualized and repeatedly reassessed.

A programmable device such as the Mindray AniFM I3 Veterinary Infusion Pump helps deliver a prescribed rate, but it cannot tell the clinician whether the patient needs additional fluid. An AniFM S3 syringe pump may be considered for compatible syringe-based therapies. Clinical response, bodyweight, fluid balance, respiratory findings and signs of overload remain part of ongoing assessment.

Respiratory compromise changes the sequence

A dyspnoeic cat is not necessarily a candidate for an immediate full workup, radiographic positioning or repeated stressful handling. Quiet observation and appropriate oxygen support may take priority while the team plans further assessment.

A clinic’s oxygen setup needs to be accessible and supported by an appropriate delivery interface. Intriquip lists the Pureline OC4000 and Pureline OC8000 among its oxygen concentrators. The manufacturer’s rated source flow does not equal the fraction of inspired oxygen reaching the patient, which depends on the complete delivery setup. Because concentrators depend on electricity, backup oxygen arrangements also matter.

The treatment area is a clinical system

The most useful readiness audit is conducted alongside the people who use the room. Can the team obtain reliable baseline monitoring? Are the correct cuff sizes accessible? Can PCV/TS and glucose be tested appropriately? Are vascular-access supplies organized? Is oxygen immediately available? Can equipment failures be managed without a scramble?

RVTs and technicians are central to repeated observations, documenting changes, equipment checks and communicating deterioration. A good monitor cannot compensate for readings that are not interpreted or shared.

The aim is not to turn every general practice into a referral centre. It is to align the team’s capabilities, equipment and transfer pathways with the emergencies the clinic is likely to see.

When the next unstable patient arrives, the first five minutes should be about identifying immediate threats and understanding what the early measurements can and cannot tell you.

For equipment planning, explore Intriquip’s veterinary equipment catalogue or contact the team to discuss the clinical work your practice needs to support.

 

Need a practical reference for the treatment area? Download our free six-page Veterinary Emergency Triage & Initial Assessment: Clinical Quick Reference. It includes a printable primary-survey checklist, PCV/TS interpretation matrix, blood-pressure measurement reminders, a fluid-therapy reassessment overview and a ready-to-use equipment checklist for your team.

 

Clinical references

Brown, A. J., & Drobatz, K. J. (2018). Triage of the emergency patient. In L. G. King & A. Boag (Eds.), BSAVA manual of canine and feline emergency and critical care (3rd ed., pp. 1–7). British Small Animal Veterinary Association.

Pardo, M., Spencer, E., Odunayo, A., Ramirez, M. L., Rudloff, E., Shafford, H., Weil, A., & Wolff, E. (2024). 2024 AAHA fluid therapy guidelines for dogs and cats. Journal of the American Animal Hospital Association, 60(4), 131–163. https://doi.org/10.5326/JAAHA-MS-7444

Savino, E., & Sierra, L. K. (2018). Team approach to the critically ill patient: The role of the veterinary nurse. In L. G. King & A. Boag (Eds.), BSAVA manual of canine and feline emergency and critical care (3rd ed., pp. 403–411). British Small Animal Veterinary Association.

Thomas, E., & Boller, E. (2018). Assessment and treatment of shock. In L. G. King & A. Boag (Eds.), BSAVA manual of canine and feline emergency and critical care (3rd ed., pp. 17–28). British Small Animal Veterinary Association.

AUTHOR CARD INTRIQUIP